PROFINET Device to Modbus Serial

Produktnummer: PLX31-PND-MBS
 

inkl. mva.

PROFINET Device to Modbus RTU/ASCII Master/Slave Gateway

The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. The serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).

The PLX31-PND-MBS gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.

Documentation & Downloads

Features and Benefits

  • PROFINET v2 certification with PROFINET class A compliance
  • Field-proven with thousands of Modbus serial devices, and multiple PROFINET controllers from multiple vendors
  • Remotely view and diagnose Modbus and PROFINET networks
  • Remote configuration via the free, intuitive, ProSoft Configuration Builder (PCB) software
  • The Modbus serial port supports master or slave mode
  • Secure module configuration via module switch (v1.04 and greater)
  • Up to 10,000 16-bit registers can be used to exchange large amounts of data.

Technical Specifications

PROFINET Specifications

     
Specification Description    
Driver Type Class A Device    
PROFINET I/O Data 1440 bytes IN, 1440 bytes OUT    
Exchange Types Cyclic Real-time (RT) and Acyclic Data    
       

Modbus Serial Specifications

 

   
Command List Up to 100 commands, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count.
Supported Modbus Function Codes 1: Read Coil Status 15: Force (Write) Multiple Coils
2: Read Input Status 16: Preset (Write) Multiple Holding Registers
3: Read Holding Registers 22: Mask Write Holding Register (slave only)
4: Read Input Registers 23: Read/Write Holding Registers (slave only)
5: Force (Write) Single Coil  
6: Preset (Write) Single Holding Register  
Software configurable communication parameters Baud rate: 110 baud to 115.2 kbps
  Parity: None, Even, Odd
  Data Size: 7 or 8 bits
  Stop bits: 1 or 2
  RTS on/off delay: 0 to 65535 milliseconds
  Modbus Modes: RTU with CRC-16, ASCII mode with LRC error checking
  Floating Point Data supported, support for Enron and Daniel
Polling of Command List Configurable polling of command list, including continuous and on change of data
Status Data Error codes available on an individual command basis. In addition, a slave status list is maintained
Node Address 1 to 247 (software selectable)
RS Interface RS232, RS422, and RS485

 

Hardware Specifications  
Specification Description
Power Supply 24 VDC nominal
 10 to 36 VDC allowed
 Positive, Negative, GND Terminals
Current Load 24 VDC nominal @ 300 mA
10 to 36 VDC @ 610 mA maximum
Operating Temperature -25°C to 70°C (-13°F to 158°F )
Storage Temperature -40°C to 80°C (-40°F to 176°F )
Relative Humidity 5% to 95% RH with no condensation
Shock IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)
IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)
Vibration IEC 60068-2-6; 5G @ 10 to 150 Hz
Dimensions 5.38 x 1.99 x 4.38 in, 13.67 x 5.05  x 11.13 cm (H x W x D)
LED Indicators For configuration and protocol status errors
Ethernet Port *10/100Mbit RJ45 Connector Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991
 *Ethernet Broadcast Storm Resiliency - less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Number of Serial Ports 1
Shipped With Each Unit 2.5 mm screwdriver, J180 Power Connector, DB9 to Screw Terminal Adapter